No Ringback Tone when making outbound calls with Grandstream IP PBX UCM63XX

No Ring Back Tone when making outbound calls with Grandstream IP PBX UCM63XX

Description No ‘ringback tone’ issue on outbound calls occurs when the PBX or UCM receives 183 Session Progress (with SDP) first and then 180 Ringing later from the SIP Service Provider (ITSP). It would be a 183 Session Progress message to play the ‘Early Media’ on the caller’s phone. Also, missing SDP in 183 Session … Read more

Grandstream UCM Remote Connect (UCMRC) Strict RTP causes no audio between IP Phones

Strict RTP Grandstream UCMRC Remote Connect

Scenario There is no audio issue in the calls between IP Phones using UCMRC. However, audio works when the call is established between the Wave app and the IP Phone with the same registered extension. Solution The “Strict RTP” option cannot be enabled while using the remote domain address of UCMRC services. When using the … Read more

Grandstream Wave iOS Crash Application Log

Description Grandstream Wave is a softphone application that allows users to make and receive phone calls over the internet using a computer, smartphone, and web browsers. This article describes the troubleshooting steps when the application crashes on iOS devices (such as iPhones and iPads). 1. Go to iPhone > Settings > Wave > Disable Contacts. … Read more

Slowness issue in Grandstream IP Phone GRP261x series

Description Slowness in IP phones can be attributed to various factors. This article suggests the troubleshooting steps to address slowness and sluggish issues in Grandstream GRP2612 or GRP2613 IP Phones: 1. Disable CPE (TR-069) under System Settings 2. Disable ‘Send SIP Logs’ and ‘Auto Recovery from Abnormality’ under Maintenance > System Diagnostics > Syslog 3. … Read more

Debugging logs required for Grandstream GWN76XX Access Point Issues

Debugging logs required for Grandstream GWN Access Point Issues

Description This article describes the required information to capture for various issues in Grandstream GWN76XX access points before submitting a helpdesk ticket. This helps the product support and development teams to understand and resolve the issue more quickly and efficiently. 1. Description of the issue (required) Clearly describe the issue you are facing with the … Read more

Syslog Server and Packet Capture Settings in Grandstream models

Maintenance Syslog Server Configuration page in Grandstream Devices

Description Syslog is a powerful tool for monitoring and troubleshooting network and system issues. This article describes the Syslog and Packet Capture settings of different Grandstream models. IP Voice Telephony GXP16XX,GXP17XX & GXP21XX GRP260X GRP261X WP810 Click here to find out more on how to use internal Syslog capture in WP810. DP75X/DP72X Facility Management GDS3710 … Read more

Grandstream IP PBX UCM’s Common Issues with SIP Trunks in India

Grandstream IP PBX UCM's Common Issues with SIP Trunks in India

Description In India, there are several telecom service providers that offer SIP trunking services to businesses and organizations. This article describes call establishment issues with Grandstream IP PBX UCM and SIP Trunks in India and suggested settings to resolve them. Case 1: Call drop due to 422 Session Interval too Small (BSNL) Figure 1: UCM’s … Read more