Granstream GWN76XX Access Point Event log: WPA-PSK deauthentication (four-way handshake failure)

Granstream GWN76XX Access Point Event log: WPA-PSK deauthentication (four-way handshake failure)

Description: Sometimes you will notice that the Grandstream GWN76XX Access Point event log shows multiple messages of WPA-PSK deauthentication (four-way handshake failure) resulting in clients’ Wifi disconnection. When the client device’s RSSI is below -70dBm, it is scanning continuously to find a new AP to roam and connect to. At around -75dBm to -80dBm, the … Read more

Grandstream GXW450X – Missing Caller ID

Missing CallerID GXW450X Grandstream

Description This article describes the issue of missing Caller ID when a call is made out from the PRI trunk to the SIP trunk via Grandstream GXW450X. Scenario E1 — GXW4502 — SIP Trunk (voipsyd06) A GXW450X is connected with a VoIP Trunk and an analog PABX on E1. When the analog PABX makes an … Read more

Common Issues and Troubleshooting with GWN76XX Access Points

Grandstream Access Point position

Description This guide summarises the common issues and troubleshooting methods listed in the official guide. Issue Troubleshooting Weak Signal 1. Remove objects2. Change locations, and avoid mounting near electronic devices3. Select 5GHz as a priority Interference(due to objects) 1. Run Wifi Analyzer to find out if the neighboring APs are using the same channel2. Reduce … Read more

Common Analog Trunk issues in Grandstream UCM63XX/62XX/6510

Description This article outlines common Analog and PSTN trunk issues encountered with Grandstream IP PBX UCM63XX/62XX/6510. It provides a list of suggestions to address various scenarios in customer setups. Issue 1: Noise or Echo Issue 2: Caller ID Not Showing or Displayed as 0000 Issue 3: FXO Port Status Not Displayed Correctly in Web Interface … Read more

Capturing Syslog and Ethernet Packets from Grandstream Devices: A Step-by-Step Guide

Capturing Syslog and Ethernet Packets from Grandstream Devices_ A Step-by-Step Guide

Description If you are new to telephony networking and troubleshooting, this guide shows you step-by-step setup and configuring the parameters to capture the packets locally in Grandstream devices. When we run into telephony issues (for eg. no audio, BLF keys are not working, unable to make calls, etc), to have the Support and Developer teams … Read more

Beep Sound Issue with Grandstream ATA HT8XX

Description When making outbound calls, the users may hear a ‘beep’ sound before ringing back or a call is established via HT8XX. Cause The ‘beep sound’ is part of the call waiting caller ID alert signal. The ‘Broadsoft’ feature requires the device to update “connected line ID” to the analog phone, upon receiving 180 Ringing. … Read more

Call Drop With Grandstream GXV3350 And Fanvil SIP Indoor Station

Description There is a call drop issue that involves Fanvil Indoor Station and Grandstream GXV3350 registered through UCM63XX. Missed calls are shown on the Fanvil SIP Indoor Station. However, a call goes through if it is dialed from GXV3240. Analysis We manage to capture the packets from UCM and analyze both good and bad calls … Read more